As part of the Professional Series, the VP600 offers outstanding UV disinfection performance for commercial applications, for flow rates up to 30 gpm (113 lpm). VIQUA Sterilight Professional Series VP600 compact UV disinfection systems provide a reliable, economical, and chemical-free way to safeguard drinking water in commercial, whole house, or a wide variety of other applications.
Features of Viqua Sterilight VP600 UV System:
- Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli, and viruses not visible to the naked eye.
- Specially designed and tested high output lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification, and offer superior performance in a wide range of water conditions.
- The system is easy to maintain and service with easy lamp and quartz sleeve replacement.
- Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
Benefits of UV Disinfection
- 99.99% destruction of bacteria, virus & protozoan cysts (Giardia Lamblia & Cryptosporidium) at rated flow.
- Chemical-free
- Easy to install and service
- Economical and energy efficient
Viqua Sterilight VP600 UV System Controller
Model: BA-ICE-C (click to enlarge)
What Size of UV System Do I Need?
|
Choose a UV System with a recommended flow that meets or exceeds your peak flow rate. When in doubt, always choose the next size up.
Don't know your flow rate?
Visit our Flow Rate & Sizing Guidefor help.
|
|
Typical Installation of VIQUA Sterilight Ultraviolet Water Treatment System.
(Click to Enlarge)
|
|
Specifications for VIQUA VP600
|
|
Sterilight Model: |
VP600 |
Recommended Flow Rate* |
30 GPM (113 LPM) |
Plug: |
N. America (NEMA P-15) |
Voltage: |
100-240v/50-60Hz |
Power Consumption: |
78W |
Connection: |
1" MNPT |
Chamber Dimensions:
|
3.5" Dia x 30.3" L (8.9 cm x 78 cm) |
Controller Dimensions:
|
9.3" x 3.25" x 2.5" (24.1 cm x 8.1 cm x 6.4 cm) |
Lamp Life: |
9,000 Hours |
Max. Operating Pressure: |
125 psi (8.62 bar) |
Inffluent Water Temperature: |
36-104ºF (2-40°C) |
Chamber Material: |
304SS |
Installation: |
Vertical or Horizontal** |
|
|
*Factory recommended flow rate is calculated at a UV dose of 30 mj/cm². See manufacturer's specification sheet for flow rates at different doses.
**Note: The ideal installation is vertical with the lamp connector on top. This is to prevent water damage from occurring on the lamp pins and lamp connector.
VP600 Controller Features
|
|
Controller: |
LCD |
Visual "Power On": |
YES |
Visual Lamp Life Remaining: |
YES |
Audible Lamp Failure: |
YES |
Audible Lamp Replacement Reminder: |
YES |
UV Sensor: |
NO* |
|
|
*For UV Sensor, use model VP600M
Replacement Parts for VP600
|
|
S600RL-HO |
UV Lamp for Viqua Sterilight VP600 |
QSO-600 |
UV Quartz Sleeve for Viqua Sterilight VP600 |
BA-ICE-C |
Controller for Viqua Sterilight VP600 |
|
|
Water Quality Parameters:
|
|
Hardness: |
< 7 grains (120 mg/L) |
Iron: |
< 0.3 mg/L |
Tannins: |
< 0.1 mg/L |
|
|
|