Validated with NSF 55 Class A, the VIQUA UV Max PRO 30 offers outstanding UV disinfection performance for commercial applications. Rated for flow rates up to 30 gpm (115 lpm) at 40 mJ/cm². VIQUA’s NSF 55 Class A Professional systems feature flow meter technology for accurate real-time UV dose measurement and reporting, together with a completely redesigned UV sensor for vastly improved reliability. LightWise Lamp Dimming Technology: Dims the lamp under no flow conditions. Benefits include:
Benefits of VIQUA UV Max PRO 30 Professional Commercial Ultraviolet Systems:
Features of UV Max PRO30 UV System:
Benefits of UV Disinfection Water Treatment
|
|
| UV Max Model: | PRO30 |
| Viqua Part Number: | 650659 |
|
Flow Rate: |
30 GPM (113 LPM) at NSF/EPA 40 mJ/cm2 |
| Certification: |
NSF/ANSI 55 for Disinfection Performance, Class A |
| Voltage: | 100-240v/50-60Hz |
| Power Consumption: | 230W |
| Connection: |
1-¼" MNPT/ 1" FNTP Combo |
| Dimensions: |
4" Dia x 41" L (10cm x 103cm) |
| Max. Operating Pressure: | 125 psi (8.62 bar) |
| Ambient Water Temperature: | 36-104ºF (2-40°C) |
| Chamber Material: | 316L SS |
| Installation: | Vertical Only |
|
|
|
Choose a UV System with a recommended flow that meets or exceeds your peak flow rate. When in doubt, always choose the next size up. Don't know your flow rate? Visit our Flow Rate & Sizing Guidefor help. |
| Controller: | LCD |
| Visual "Power On": | YES |
| Visual Lamp Life Remaining: | YES |
| Audible Lamp Failure: | YES |
| Audible Lamp Replacement Reminder: | YES |
| UV Sensor: | YES |
| Flow Meter: | YES |
| Cool Touch Fan: | YES |
| 602856 | UV Lamp for Trojan UV Max PRO30 |
| 602976 | UV Quartz Sleeve for UV Max PRO30 |
| 602580 | UV Sensor for UV Max PRO30 |
| 650709-009 | Power Supply for PRO30 |

VIQUA’s new LightWise™ technology allows the system’s electronic controller to automatically reduce lamp power during periods of no water flow, reducing the rate of sleeve fouling by up to 60%, and providing estimated energy savings of 30% compared to standard PRO systems. By adjusting the lamp power, water temperature is maintained below 40˚C (104˚F), and the rate of sleeve fouling is consequently reduced by as much as 60%. This can more than double the amount of time between cleanings in the sleeve cleaning maintenance cycle.
In many situations, the most common problem affecting ultraviolet (UV) water disinfection is the fouling of the quartz sleeve which surrounds the UV lamp. The rate of sleeve fouling is influenced by water temperature, water flow, and water quality – specifically the concentrations of calcium, magnesium, and iron in the water, which are the most common constituents that lead to sleeve fouling. Under no-flow conditions through the UV chamber, the water temperature increases, which causes an accelerated rate of calcium, magnesium, and iron deposits precipitating onto the quartz sleeve. This decreases the level of UV transmittance and eventually requires the sleeve to be cleaned. While actual water usage may vary significantly in a 24-hour period, conditions of no water flow typically account for as much as 60% of the day. During this time, the UV lamp heats the water, resulting in water temperatures as high as 55˚C (131˚F) in the chamber and significantly increasing the rate of sleeve fouling.
VIQUA’s new LightWise technology allows the controller to reduce lamp power during periods of no water flow, leading to estimated energy savings of 30%. By adjusting the lamp power, water temperature is maintained below 40˚C (104˚F), and the rate of sleeve fouling is consequently reduced by as much as 60%. This can more than double the amount of time between sleeve cleaning cycles.