FILMTEC™ XLE PRO-4040 Brackish Water Reverse Osmosis Membrane Element
DUPONT FILMTEC™ XLE PRO-4040 Elements offer better system performance and economics for small commercial systems by operating at very low applied pressure. FILMTEC XLE PRO-4040 elements are tape-wrapped. In addition to high quality water and low energy costs, FILMTEC membranes also deliver savings by providing long lasting and reliable performance. For added convenience, the elements are available in a dry state for rapid start-up.
FILMTEC Brackish Water Reverse Osmosis Elements can separate salts from water and are produced with an automated fabrication process for precision, consistency, and reliability. FILMTEC RO membranes build on a tradition of leadership in the thin-film composite membrane industry and meet the challenges of higher rejection in lower-pressure operations.
DOW and Dupont merged and DOW FilmTec membranes are now sold as DUPONT FilmTec. FilmTec XLE-4040 membrane element has been discontinued by the manufacturer. XLE PRO-4040 is the direct replacement.
|
|
Specifications for XLE PRO-4040
|
|
FilmTec Product: |
XLE PRO-4040 |
FilmTec Part Number: |
12082995 |
Replaces FilmTec Parts: |
XLE-4040 154546 |
Size (Approximate): |
4" Dia. x 40"L |
Flow Rate: |
2,750 gpd (10.4 m³/d) |
Applied Pressure: |
125 psig (8.7 bar) |
Stabilized Salt Rejection: |
99.0% |
Minimum Salt Rejection: |
970% |
Single Element Recovery: |
15% |
Exterior: |
Tape-Wrapped |
Membrane Type:
|
Polyamide Thin-Film Composite |
|
|
Permeate flow and salt rejection based on the following test conditions: 77°F (25°C), 15% recovery, applied pressure 125 psig (8.7 bar), pH 8, and based on a 2,000 ppm NaCl feed stream
Operating Limits for XLE PRO-4040
|
|
Maximum Operating Temperature: |
113°F (45°C)
|
Maximum Operating Pressure: |
600 psig (41 bar) |
Maximum Pressure Drop: |
13 psig (0.9 bar) |
Maximum Feed Flow Rate: |
14 gpm (3.2m³/h)
|
pH Range, Continuous Operation*: |
2-11 |
pH Range, Short-Term Cleaning**: |
1-13 |
Maximum Feed Silt Density Index: |
5 |
Fere Clorine Tolerance***: |
<0.1ppm |
|
|
*Maximum temperature for continuous operation above pH 10 is 95°F **Refer to cleaning guidelines. ***Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine by pretreatment prior to membrane exposure.
|